2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power

Anhui Tongdu International Trade Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power

Model Number : ZR-YJV 2*50mm²

Conductor nominal area (per core) : 50 mm²

Volume resistivity @90 °C : ≥ 10¹² Ω·cm

MOQ : 100 meters

Packaging Details : General Packaging or As Requirements

Conductor diameter (approx.) : 9.0mm

Filler / binder : FR PP filler + FR tape

Routine test : 3.5 kV AC / 5 min; type test 4.0 kV

Short-circuit temp. (≤5 s) : 250 °C

Sheath thickness : 1.8 mm

Supply Ability : 10000 meters per month

Insulation thickness : 1.0 mm (50 mm² class)

Approx. weight : 720 – 800 kg/km,use ≈ 760 kg/km

Emergency overload : 105–130 °C

Certification : CE/ISO/CCC

Number of cores : 2

Brand Name : TONGDU

Conductor (×2) : Bare annealed copper, Class 2 stranded, 19×∅1.78 mm, conductor Ø ≈ 9.0 mm

Place of Origin : China

Conductor construction : Class 2, 19×∅1.78 mm,min. 19 wires

Payment Terms : L/C,T/T

Insulation (×2) : XLPE

Long-term service temp. : 90 °C

Delivery Time : Less than 15 days

Diameter over insulated core : 11.0 mm (9.0 + 2×1.0)

Overall cable diameter : 22.5 – 23.5 mm

Contact Now

ZR-YJV 2*50mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C — IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

2×50 mm²

Two cores, 50 mm² copper conductor each


Construction: Two Class 2 stranded copper conductors, XLPE insulation, PVC outer sheath (no armour, no shield, circular formation).

ZR-YJV 2×50 mm² — Cable Data Report

1. Product Summary. ZR-YJV 2×50 is a two-core flame-retardant power cable — twin 50 mm² copper conductors, XLPE insulation, PVC sheath, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz. Conformance: GB/T 12706.1 / IEC 60502-1, core GB/T 3956 / IEC 60228, fire GB/T 19666 / GB/T 18380 (default ZC).


2. Construction Overview. Core-to-jacket stack:


Layer Build Wall Diameter
Conductor (×2) Annealed copper, Class 2, 10 × 2.52 mm (10/2.52) each, 50 mm² per core — ≈ 8.3 mm per core
Insulation (×2) Cross-linked polyethylene 1.0 mm ≈ 10.3 mm per core (over ins.)
Lay-up Two cores + non-hygroscopic filler, optional binder tape — ≈ 20.6 mm
Sheath Flame-retarded PVC, ST2, black 1.8 mm ≈ 26.2 mm overall

Weight ≈ 1194 kg/km (Al version ≈ 588.6).


2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power


3. Electrical Ratings. DC resistance ≤ 0.387 Ω/km per core @ 20 °C; routine 3.5 kV / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; typical insulation resistance ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km per core. Reference ampacity (both cores loaded) ≈ 226 A in air (30 °C) and ≈ 275 A direct-buried (20 °C) per Chengtantai; Mingda's table quotes 190 A/210 A @25 °C — derate per GB/T 16895 / IEC 60364.


Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu, per core)

≤ 0.387 Ω/km

GB/T 3956 max

AC resistance @90 °C (est.)

≈ 0.503 Ω/km

per core

Current rating in air (30 °C, single circuit, 2-core)

≈ 125 – 135 A

design ≈ 130 A

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 155 – 170 A

design ≈ 163 A

Short-circuit current (1 s, Cu, 250 °C, per core)

≈ 5.00 kA

reference

Frequency

50/60 Hz AC (DC usable)

—

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene), Type TR-XLPE

Outer sheath material

PVC (polyvinyl chloride), Type ST₂

Long-term service temp.

90 °C (continuous, XLPE insulation)

Short-circuit temp. (≤5 s)

250 °C (Cu conductor limit for XLPE)

Emergency overload temp.

130 °C (short term, ≤1 h)

Test voltage AC (5 min)

3.5 kV (routine test, 0.6/1 kV class)

Dielectric strength

≥ 20 kV/mm (room temp.)

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None​ (unshielded design)


4. Thermal & Bending. Continuous 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; minimum bend radius ≥ 15 × OD (multi-core).


ZR-YJV 2×50 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Two-Core)
Construction: CU / XLPE / PVC, 2 cores • Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance) • Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (two-core) — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 2×50 — 2 cores × 50 mm²; Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 2 — Two-core cable; phase + neutral (L+N) duty
7 Identification Nominal cross-sectional area 50 mm² Per core; nominal cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction (per core) 10 wires × 2.52 mm (10/2.52) — Class 2 round stranded; nominal section 50 mm² per core
11 Conductor Conductor diameter (per core) ≈ 8.3 mm Ø of the 10/2.52 stranded core (8.0–8.4 mm across practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.387 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 50 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.0 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 50 mm²)
15 Insulation Diameter over insulation (per core) ≈ 10.3 mm ≈ 8.3 + 2 × 1.0 (calculated)
16 Lay-up Core assembly Two insulated cores laid up with non-hygroscopic filler; optional binder tape — Round construction, right-hand lay
17 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
18 Sheath Nominal sheath thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (Mingda two-core table)
19 Dimensions Approx. overall diameter 26.2 mm Mingda unarmored table 26.2; armored YJV22 2×50 ≈ 28.0 mm
20 Dimensions Approx. cable weight ≈ 1194 kg/km Mingda 1194 (aluminium version ≈ 588.6 kg/km); armored YJV22 2×50 ≈ 1412 kg/km
C. Electrical Performance
21 Electrical Max. DC conductor resistance at 20 °C 0.387 Ω/km GB/T 3956; routine measurement
22 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
23 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables
24 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
25 Electrical Capacitance (approx., per core) ≤ 0.45 μF/km Manufacturer reference value
26 Electrical Reference ampacity — in air, 30 °C, both cores loaded ≈ 226 A Chengtantai two-core table (226 A Cu); Mingda quotes 190 A @25 °C — derate per GB/T 16895 / IEC 60364
27 Electrical Reference ampacity — direct burial, 20 °C ≈ 275 A Chengtantai two-core table (275 A Cu); Mingda quotes 210 A @25 °C — depends on soil thermal resistivity
D. Thermal Performance
28 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
29 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
30 Thermal Ambient service temperature range -20 to +45 °C Per manufacturer datasheet family; check project specification
31 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
32 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
33 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
34 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
35 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
36 Installation Min. bending radius — multi-core cable ≥ 15 × OD — GB 50168 practice for multi-core XLPE cables; OD = actual cable diameter
37 Installation Laying methods Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial — Also direct burial with mechanical protection where permitted
38 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
39 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
40 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
41 Packing Packing form Coil (carton drum) / wooden drum / export packing — As per customer requirement


5.Test Parameters


ZR-YJV 2×50 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.387 Ω/km at 20 °C (per core) Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between each conductor and earth/water; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.0 mm nominal; sheath ≥ 1.8 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 10 × 2.52 mm; Ø ≈ 8.3 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD (multi-core)
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


6. Fire Behaviour. Passes GB/T 18380.12 single burn and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC contains halogen — WDZ-YJY for LSZH duty.


Technical Datasheet — Flame-Retardant (FR) Characteristics
ZR-YJV 0.6/1 kV 2 × 50 mm² (Cu / XLPE / FR-PVC)





1. Cable Identification




Code / Item Meaning / Value Standard / Note

ZR Flame Retardant (legacy prefix); under GB/T 19666-2019 defaults to Class C; modern equivalent = ZC GB/T 19666-2019

YJ XLPE — cross-linked polyethylene insulation —

V PVC outer sheath — flame-retardant grade, contains halogen (Cl) GB/T 19666-2019

0.6/1 kV Rated voltage U₀/U = 600/1000 V; maximum Uₘ = 1.2 kV IEC 60502-1

2 × 50 mm² Two cores, nominal copper conductor area 50 mm² per core (both cores equal) —

Construction Unarmoured, non-screened, round multi-core —

Application note Two-core → single-phase AC (L+N) or DC pair (+, −) —
2. Flame-Retardant & Fire Performance (CORE)

Property Value / Requirement Standard

Flame Retardant Class Class C (bundled cables, char length ≤ 2.5 m) GB/T 19666-2019; GB/T 18380.3 / IEC 60332-3-24

Legacy designation ZR (= ZC); modern prefix preferred: ZC GB/T 19666-2019

Test method — flame Bunched flame test (category C), char ≤ 2.5 m after flame removal GB/T 18380.3 (IEC 60332-3-24)

Halogen content Contains halogen — Cl from PVC sheath; releases HCl on burning GB/T 17650 / IEC 60754-1/-2

Smoke density Heavy dark smoke — NOT low-smoke (no LSZH certification) GB/T 17651 / IEC 61034

Corrosivity Corrosive — HCl gas generated during fire GB/T 17650 / IEC 60754-2

pH / conductivity of gases Not certified (PVC base — acidic / conductive combustion gases) GB/T 17650 / IEC 60754-2

Limited Oxygen Index (LOI) PVC typical ≈ 45–49 % O₂ (reference, design value) ASTM D2863 / GB/T 2406, reference

Max. conductor operating temp. 90 °C (long-term service) GB/T 12706.1-2020

Max. short-circuit temp. (≤5 s) 250 °C IEC 60502-1

Emergency overload temp. 105 °C (up to 130 °C transient) IEC 60502-1

Service ambient range (PVC sheath) −15 °C to +90 °C —

Min. installation ambient temp. 0 °C (pre-heat required below 0 °C) —
Note: ZR = Flame Retardant only — it does NOT imply low-smoke (LSZH) or fire-survival. PVC sheath is halogenated; upgrade to WDZ-YJY for LSZH or NH-ZR-YJV for fire-survival circuits.
3. Fire Test Summary

Test Requirement ZR-YJV 2×50 Verdict

Bunched flame test (Class C) Char length ≤ 2.5 m ✅ PASS (design, Class C)

Single flame test (IEC 60332-1) Self-extinguishing ✅ PASS (XLPE/PVC FR)

Smoke density (IEC 61034) Light transmittance ≥ 60 % for LSZH ❌ NOT applicable (PVC → heavy smoke)

Halogen content (IEC 60754) ≤ 0.5 % HCl for LSZH ❌ NOT applicable (contains Cl)

Acidity / corrosivity (IEC 60754-2) pH ≥ 4.3; conductivity ≤ 10 µS/mm for LSZH ❌ NOT certified (corrosive HCl)

Fire-survival (BS 6387 / IEC 60331) Circuit integrity during/after fire ❌ NOT applicable — use NH-ZR-YJV
4. Key Electrical & Thermal Parameters

Parameter Value Note

Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV

Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1

Type-test voltage 4.0 kV IEC 60502-1

DC resistance @ 20 °C (per core) ≤ 0.387 Ω/km GB/T 3956 / IEC 60228, Class 2 max

AC resistance @ 90 °C (est.) ≈ 0.503 Ω/km per core

Current rating — in air (30 °C, single circuit) ≈ 125–135 A (design ≈ 130 A) 2-core

Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 155–170 A (design ≈ 163 A) 2-core

Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 5.00 kA reference

Frequency 50/60 Hz AC (DC usable) —
Design recommendation: ≈ 130 A in air / ≈ 163 A buried, then apply grouping & ambient temperature correction. Buried rating > air rating due to better heat dissipation & different reference conditions.
5. Construction & Material Specification

Layer (inside → out) Description / Specification FR Contribution

Conductor (×2) Bare annealed copper, Class 2 stranded, 19×∅1.78 mm, conductor Ø ≈ 9.0 mm None (Cu non-combustible)

Conductor screen Omitted (not required for 0.6/1 kV) —

Insulation (×2) XLPE, colours: red / black / blue etc., 1.0 mm nominal XLPE — low flame spread

Filler Flame-retardant PP / PE to form round assembly ✅ FR additive

Binder Flame-retardant tape over laid-up cores ✅ FR barrier

Outer sheath Flame-retardant PVC (ZR grade), 1.8 mm nominal, black ✅ Primary FR layer (halogenated)

Armour None —

Metallic screen None —
6. Dimensional Data

Item Typical Value Remarks

Conductor nominal area (per core) 50 mm² —

Number of cores 2 —

Conductor construction Class 2, 19×∅1.78 mm min. 19 wires

Conductor diameter (approx.) 9.0 mm —

Insulation thickness 1.0 mm 50 mm² class

Diameter over insulated core 11.0 mm 9.0 + 2×1.0

Sheath thickness 1.8 mm multi-core rule, ≥ 1.8 mm

Overall cable diameter 22.5 – 23.5 mm (use 23.0 mm for design) —

Approx. weight 720 – 800 kg/km (use ≈ 760 kg/km) —

Cable shape Round —
7. Mechanical & Installation Parameters

Parameter Value Note

Minimum bending radius (unarmoured multi-core) ≥ 15 × OD ≈ 345 mm @ Ø23.0 mm —

Max. pulling tension (Cu only) 50 N/mm² × 50 mm² × 2 = 5,000 N total use conductor sock, avoid sheath grip

Direct burial Allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 2×50 —

Conduit ID ≥ 1.5 × OD → ≥ 35 mm (use 40 mm or 50 mm conduit) —

Elevation difference limit None (XLPE) —
8. Selection Guide — When FR Matters

Scenario Recommended Cable Reason

Flame-retardant, halogenated acceptable (standard) ZR-YJV 2×50 (this cable) Class C FR, PVC sheath, cost-effective

Low-smoke halogen-free required (LSZH) WDZ-YJY 2×50 LSZH sheath — IEC 61034 / IEC 60754 compliant

Fire-survival circuit (circuit integrity) NH-ZR-YJV 2×50 BS 6387 / IEC 60331 fire-survival grade

Heavy mechanical load / direct burial risk ZR-YJV22 2×50 Steel-tape armoured version

Three-phase circuit 3 / 4 / 5-core version 2-core unsuitable for 3-phase
Applicable standards: GB/T 12706.1-2020 (equiv. IEC 60502-1) · GB/T 3956 / IEC 60228 · GB/T 19666-2019 · GB/T 18380.3 · GB/T 17651 / IEC 61034 · GB/T 17650 / IEC 60754. | Packing: steel-wooden drum or coil, 100–500 m typical. | HS code (China): 8544 4921.
⚠ Values are typical / design reference. Always confirm with manufacturer test reports & relevant local regulations before final specification.


7. Verification. Routine: resistance, 3.5 kV/5 min, dimension audit (ins. ≥ 1.0 mm, sheath ≥ 1.8 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018).


Technical Datasheet — Insulation Test Data / ZR-YJV 0.6/1 kV 2×50 mm²
XLPE Insulated, Flame-Retardant PVC Sheathed Power Cable — Insulation Characteristics & Test Schedule






1. Cable Identification
# Item Value Unit Standard / Reference Remarks
1 Cable designation ZR-YJV 0.6/1 kV 2×50 — GB/T 12706.1-2020 (IEC 60502-1) Unarmoured, non-screened, round
2 Conductor material Bare annealed copper — GB/T 3956 / IEC 60228 Class 2 stranded
3 Conductor construction 19 × Ø1.78 mm IEC 60228 min. 19 wires
4 Conductor nominal area (per core) 50 mm² GB/T 3956 Both cores 50 mm²
5 Number of cores 2 — — L+N (AC) or +/− (DC)
6 Insulation material XLPE (cross-linked polyethylene) — GB/T 12706.1-2020 Cross-linked polyethylene
7 Sheath material Flame-retardant PVC (ZR) — GB/T 19666-2019 Contains halogen (Cl)
8 Rated voltage U₀/U 0.6 / 1 kV IEC 60502-1 Uₘ = 1.2 kV






2. Insulation Design Data
# Item Value Unit Standard / Reference Remarks
1 Insulation material XLPE — GB/T 12706.1-2020 Cross-linked polyethylene
2 Nominal insulation thickness 1.0 mm GB/T 12706.1-2020, Tab. 3 50 mm² class
3 Minimum insulation thickness (allowable) 0.80 mm GB/T 12706.1-2020 90% × 1.0 − 0.1 mm
4 Insulator colour (typical) Red / Black / Blue — GB/T 6995 / IEC 60227 Per phase / neutral
5 Diameter over insulated core 11.0 mm Calculated Conductor 9.0 + 2×1.0
6 Conductor diameter (approx.) 9.0 mm Calculated 19 × Ø1.78 mm
7 Volume resistivity @ 90 °C ≥ 10¹² Ω·cm GB/T 12706.1-2020 XLPE typical
8 Dielectric loss factor tan δ < 0.001 — IEC 60502-2 (ref.) XLPE, 20 °C, 50 Hz
9 Relative permittivity εᵣ 2.3 – 2.5 — Material data XLPE typical






3. Thermal Characteristics of Insulation
# Item Value Unit Standard / Reference Remarks
1 Maximum conductor operating temp. (long-term) 90 °C GB/T 12706.1-2020 XLPE rated
2 Maximum short-circuit temp. (≤ 5 s) 250 °C IEC 60502-1 Copper conductor
3 Emergency overload temp. (short-term) 105 – 130 °C GB/T 12706.1-2020 Limited duration
4 Minimum installation ambient temp. 0 °C GB/T 12706.1-2020 Pre-heat below 0 °C
5 Service ambient range (PVC sheath) −15 to +90 °C GB/T 19666-2019 Sheath limit
6 Thermal stability (XLPE) Stable to ≥ 250 °C Material data Cross-linked






4. Insulation Test Schedule (Routine / Type / Sample)
# Test Item Test Value / Condition Result Standard / Reference Remarks
1 Routine spark / withstand test (insulated core) 3.5 kV AC, 5 min PASS GB/T 12706.1-2020 / IEC 60502-1 Applied per core
2 Type test — AC withstand voltage 4.0 kV AC, 4 h PASS IEC 60502-1 After laying-up
3 Partial discharge test (type) ≤ 10 pC @ 1.73 U₀ PASS GB/T 12706.1-2020 / IEC 60502-1 XLPE, 1.73 kV
4 Insulation resistance (DC, 20 °C) ≥ 200 MΩ·km — GB/T 3048 / IEC 60060 Reference value
5 Volume resistivity @ 90 °C ≥ 10¹² Ω·cm PASS GB/T 12706.1-2020 Material check
6 Tangent delta (tan δ) — dielectric loss < 0.001 (20 °C, 50 Hz) PASS IEC 60502-2 (ref.) Low loss material
7 Hot-set test (cross-linking / XLPE) 200 °C, 15 min, load 20 N/cm² PASS IEC 60811-507 / GB/T 2951 Elongation / set
8 Aging in air (thermal endurance) 135 °C, 7 d (or per Arrhenius) PASS IEC 60811-401 / GB/T 2951 Tensile retained ≥ 80%
9 Tensile strength (XLPE insulation) ≥ 12.5 MPa MPa IEC 60811 / GB/T 2951 Before aging
10 Elongation at break (XLPE insulation) ≥ 200 % % IEC 60811 / GB/T 2951 Before aging
11 Cold bend test (insulation) −15 °C, 4 h, bend radius 5D No crack IEC 60811-404 / GB/T 2951 Applicable to PVC; XLPE no effect
12 Water absorption (XLPE, type) ≤ 10 mg / cm² mg/cm² IEC 60502-2 (ref.) Long-term moisture
13 Dielectric strength (breakdown voltage) ≥ 20 kV/mm (typical) kV/mm Material data XLPE intrinsic
14 Conductor DC resistance @ 20 °C ≤ 0.387 Ω/km Ω/km GB/T 3956 / IEC 60228 Class 2 copper, per core
15 Short-circuit current rating (1 s, 250 °C) ≈ 5.00 kA kA IEC 60364 / calculated Per core, reference






5. Electrical Parameters (Derived from Insulation & Conductor)
# Parameter Value Unit Standard / Reference Remarks
1 Rated voltage U₀/U 0.6 / 1 kV IEC 60502-1 Uₘ = 1.2 kV
2 DC resistance @ 20 °C (per core) ≤ 0.387 Ω/km GB/T 3956 Class 2 copper
3 AC resistance @ 90 °C (est., per core) ≈ 0.503 Ω/km Calculated (α = 0.00393/K) R₂₀ × [1+α(90−20)]
4 Current rating — in air (30 °C, single circuit) ≈ 125 – 135 (design ≈ 130) A IEC 60287 / GB/T 16895 2-core, apply correction
5 Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 155 – 170 (design ≈ 163) A IEC 60287 / GB/T 16895 2-core, apply correction
6 Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1 Routine test
7 Type-test voltage 4.0 kV IEC 60502-1 Type test
8 Frequency 50 / 60 Hz AC (DC usable) Hz — —






6. Dimensional / Inspection Result
# Item Design Value Measured (example) Tolerance Verdict
1 Conductor nominal area (per core) 50 mm² 50.0 mm² ± 0 % (nom.) OK
2 Number of wires 19 19 min. 19 OK
3 Wire diameter Ø1.78 mm Ø1.77 mm ± 1 % OK
4 Conductor diameter 9.0 mm 9.02 mm ± 2 % OK
5 Insulation thickness (nominal) 1.0 mm 1.02 mm −10 % + none OK
6 Minimum insulation thickness 0.80 mm 0.94 mm ≥ 0.80 mm OK
7 Diameter over insulated core 11.0 mm 11.06 mm ± 5 % OK
8 Overall cable diameter 22.5 – 23.5 (design 23.0) mm 23.1 mm ± 5 % OK
9 Sheath thickness 1.8 mm 1.81 mm −10 % + none OK
10 Approx. weight 720 – 800 (≈ 760) kg/km 758 kg/km ± 5 % OK






Notes
1. All insulation tests shall be carried out at (20 ± 5) °C and 45 – 75 % RH unless otherwise stated.
2. Routine test = 100 % production test; Type test = performed on representative samples; Sample test = per lot.
3. Test voltage 3.5 kV / 5 min is the routine withstand test per IEC 60502-1; 4.0 kV is the type-test voltage.
4. Values marked 'typical' or 'reference' are material / design values; confirm against the manufacturer's test report (TDS / CoC).
5. Current ratings are for a single circuit, unarmoured 2×50 mm²; apply correction factors for grouping, ambient temperature, soil thermal resistivity and depth.
6. XLPE insulation is rated 90 °C long-term / 250 °C short-circuit (≤ 5 s); do not exceed these limits in service.
7. For low-smoke halogen-free requirement → WDZ-YJY 2×50; for fire-survival circuits → NH-ZR-YJV 2×50; for heavy mechanical load → ZR-YJV22 2×50.
8. Standards: GB/T 12706.1-2020 (equiv. IEC 60502-1); GB/T 3956 / IEC 60228; GB/T 19666-2019; GB/T 2951 / IEC 60811; GB/T 3048.


8. Cross Section Structure


2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power


ZR-YJV 2×50 mm² — Cable Cross-Section Structure (Schematic)
Two-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 2 Annealed copper, Class 2 stranded — 10 × 2.52 mm per core (10/2.52), nominal 50 mm² per core — ≈ 8.3 (Ø per core) Current-carrying element; max DC resistance ≤ 0.387 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 2 Cross-linked polyethylene 1 ≈ 10.3 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Two insulated cores laid up with non-hygroscopic filler; optional binder tape — ≈ 20.6 (Ø over lay-up) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.8 ≈ 26.2 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 26.2 mm Mingda unarmored 26.2; armored YJV22 ≈ 28.0

Approx. cable weight ≈ 1194 kg/km Mingda 1194 (Al 588.6); armored YJV22 2×50 ≈ 1412 kg/km

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666


Product Structure Introduction — ZR-YJV 2×50 mm² (English)
Two-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV

1. Purpose & Product Identity
ZR-YJV 2×50 is a flame-retardant twin-core low-voltage feeder, 0.6/1 kV AC, in the conventional copper / XLPE / PVC family. Manufacture follows GB/T 12706.1 / IEC 60502-1, cores per GB/T 3956 / IEC 60228 and fire class per GB/T 19666 (ZC unless a higher class is ordered). Overall diameter ≈ 26.2 mm, weight ≈ 1194 kg/km, normally supplied in 100 m drums.
Both cores are symmetrical live conductors intended for single-phase circuits; the product is not rated for flexible duty.

2. Conductor Sub-Assembly
Each core is built from ten soft-drawn copper wires of 2.52 mm (10/2.52), stranded to Class 2 with a nominal 50 mm² section and ≈ 8.3 mm diameter. Per-core DC resistance is held at or below 0.387 Ω/km at 20 °C, keeping 50 mm² in the 226 A air-current class while remaining flexible enough for duct pulling.

3. Dielectric Sub-Assembly
A 1.0 mm XLPE insulation coats every core, bringing the diameter over insulation to ≈ 10.3 mm. The cross-linked dielectric is good for 90 °C continuous running and 250 °C for five seconds on fault, shows volume resistivity of at least 1×10¹² Ω·cm and clears the 3.5 kV / 5 min routine voltage test.

4. Core Assembly & Outer Jacket
The two insulated cores are cabled together with dry, non-hygroscopic fillers (a binder tape is optional), giving a round core assembly of ≈ 20.6 mm. Over this sits a 1.8 mm flame-retarded PVC (ST2) jacket, closing the cable to ≈ 26.2 mm. The ZC flame rating is verified by GB/T 18380.12 and class-C GB/T 18380.35; because the jacket is halogen-bearing PVC, WDZ-YJY should be specified where zero-halogen is mandatory.

5. Handling & Application Advice
• Minimum bending radius 15 × OD; pull with a proper stocking, never on the core. • Post-installation DC test 4U0 = 2.4 kV for 15 minutes. • Ambient −20 to +45 °C, warm before laying below 0 °C. • Ratings are whole-cable values — apply ambient, grouping and burial derating. • Use lugs sized for the ≈ 8.3 mm conductor.


9. Usage Cautions. Bend ≥ 15 × OD; pull by stocking, never by the cores; avoid kinking; shield from UV and mechanical impact; run the DC site test before energising; load both cores symmetrically; match lugs to the ≈ 8.3 mm core.


2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power


10. Application Range. Single-phase feeders, L+N distribution, main sub-boards, pump, HVAC and machine feeders at 0.6/1 kV — conduits, trays, trunking, trenches; indoor or sheltered outdoor.


2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power


11. Ordering Information. ZR-YJV 0.6/1 kV 2×50, length, coil/drum type, marking. Standard 100 m; confirm all figures against the factory certificate.


2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power


ZC-YJV 2×50 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “2×50 mm²” indicate?
“2” means the cable has two cores (two insulated conductors within a common sheath). “50 mm²” is the nominal cross-sectional area of each copper conductor. This 2-core size is commonly used for single-phase main branch feeders and moderate-to-high current single-phase load connections in commercial and industrial installations.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE) on each core. Filler: non-hygroscopic material. Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial or mechanical protection needs, armored variants such as ZC-YJV22 (double steel tape armor) are available.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides excellent thermal stability and high current-carrying capacity for power distribution applications.
Q6. What is the typical current-carrying capacity?
For a 2×50 mm² copper XLPE cable, the ampacity is approximately 145–180 A when installed in free air at 30 °C ambient. Multi-core cables have slightly lower ampacity than equivalent single-core cables due to mutual heating between cores. Lower ratings apply when buried, installed in conduit, grouped, or at elevated ambient temperatures. Refer to GB/T 16895 / IEC 60364 and manufacturer ampacity tables for precise engineering values.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 50 mm² Class 2 copper conductor at 20 °C is approximately 0.387 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. Each core in the 2-core cable has the same resistance value. Confirm the exact value from the factory test report for each batch.

Installation & Applications

Q8. What is the minimum bending radius?
For multi-core unarmored cables, the minimum bending radius is 15 times the cable outer diameter (15D) during installation. Multi-core cables are generally more flexible than single-core cables of equivalent conductor cross-section. D = actual outer diameter.
Q9. What are the typical applications?
Common uses include: single-phase main branch circuits in commercial and residential buildings; power supply to medium-to-large motors, compressors, and HVAC systems; distribution board outgoing feeders for single-phase load groups; and secondary power distribution in industrial facilities where Class C flame-retardant performance is required.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.

Product Tags:

2 x 50mm2 2 core shielded cable

      

Construction Power 2 core shielded cable

      

pvc jacket wire IEC 60502-1

      
China 2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power factory

2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Tongdu International Trade Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)